logo
المنزل > المنتجات >
تحديد عيب الكابل
>
Cable Fault Locator with Adjustable ≥15kV Voltage for Outer Sleeve Failure Detection and TDR Technology

Cable Fault Locator with Adjustable ≥15kV Voltage for Outer Sleeve Failure Detection and TDR Technology

تفاصيل المنتج:
مكان المنشأ: شيآن شنشي الصين
اسم العلامة التجارية: XZH TEST
إصدار الشهادات: ISO CE
رقم الموديل: XHHG520
معلومات مفصلة
مكان المنشأ:
شيآن شنشي الصين
اسم العلامة التجارية:
XZH TEST
إصدار الشهادات:
ISO CE
رقم الموديل:
XHHG520
إبراز:

High Light

إبراز:

Adjustable ≥15kV Cable Fault Locator,Outer sleeve failure Cable Fault Detector,TDR Cable Tester

,

Outer sleeve failure Cable Fault Detector

,

TDR Cable Tester

Trading Information
الحد الأدنى لكمية:
1 مجموعة
تفاصيل التغليف:
عبوة خشبية
وقت التسليم:
5-8 أيام عمل
شروط الدفع:
تي/تي
القدرة على العرض:
3000 وحدة / سنة
وصف المنتج
XHHG520
Professional-grade cable fault locator designed for detecting and locating outer sleeve failures in high-voltage cables.
The cable outer sheath fault tester is designed based on the Murray bridge principle and can be used to locate breakdown points and defects in various wires and cables that are not broken down but have low insulation resistance values.
Features
  • Adjustable voltage output ≥15kV
  • Specialized for outer sleeve failure detection
  • Precision locating capabilities
  • Adjustable output voltage;
  • High accuracy and stability;
  •  Employs a high-sensitivity amplifier and galvanometer for balance indication;
  • Zero-point protection;
  • Automatic fault point detection, while retaining manual testing functionality;
Key Specification Value
Voltage Range ≥15kV (adjustable)
Primary Application Outer sleeve failure detection

Cable Fault Locator with Adjustable ≥15kV Voltage for Outer Sleeve Failure Detection and TDR Technology 0

The cable outer sheath fault tester is particularly suitable for:

1. High-resistance breakdown points in cables after installation, especially linear high-resistance breakdown points that are difficult to burn into low-resistance conditions, such as linear high-resistance breakdowns at cable joints.

2. Flashover-type breakdown points, where the constant current source can maintain the arc after breakdown, a stable current flows through the bridge, and the bridge has sufficient sensitivity.

3. Defects that have not yet broken down but have low resistance, such as insulation defects where a megohmmeter reveals a low cable resistance value, but the cable does not break down under operating voltage.