60kv رقمية حرق من خلال جسر كابل تحت الأرض العيب المحدد

تحديد عيب الكابل
July 17, 2025
اتصال الفئة: تحديد عيب الكابل
موجز: Discover the 60kV Digital Burn-Through Bridge Cable Fault Locator, a cutting-edge tool for pinpointing insulation faults in high-voltage, large-section, and complex cable systems. This intelligent device combines burn-through and bridge functions, offering high accuracy and efficiency without removing GIS switches or cross interconnections. Perfect for professionals in the electrical and utility sectors.
ميزات المنتج ذات الصلة:
  • Integrated burn-through and intelligent bridge functions for versatile fault location.
  • Rated voltage of 60kV in burn mode with a short circuit current of 400mA for quick high-resistance fault conversion.
  • Intelligent bridge mode with a 750mA working current for enhanced fault location accuracy.
  • Switching power supply ensures high-voltage, stable current output for reliable performance.
  • Large LCD screen display at high potential with ground-potential operating buttons for safety.
  • Portable design in a lightweight pull-rod plastic box for easy transport and operation.
  • No blind spots in bridge mode, ideal for short cables and near-end breakdown points.
  • High voltage and high current capabilities suit complex, long, and large-section cable systems.
الأسئلة:
  • What types of cable faults can the 60kV Digital Burn-Through Bridge locate?
    It can locate all cable insulation and sheath faults except some short line faults, making it ideal for high-voltage, large-section, and complex cable systems.
  • How does the device improve fault location accuracy?
    The intelligent bridge mode operates at 750mA, significantly enhancing accuracy, while the burn-through mode quickly converts high-resistance faults to low-resistance for easier detection.
  • Is the device suitable for use with GIS terminals and cross interconnections?
    Yes, it is specially designed for insulation fault location in complex high-voltage cables with GIS terminals and cross interconnections, allowing quick location without removing GIS switches or short-circuiting cross interconnections.
فيديوهات ذات صلة

مسدس ربط الكابل XHZS506S

تحديد عيب الكابل
December 22, 2025

Cable Fault Piercing XHZS506Y

تحديد عيب الكابل
December 19, 2025

XHGG502A تحديد خطأ الكابل

فيديوهات أخرى
October 31, 2024

سلسلة XHDP

فيديوهات أخرى
November 05, 2024

XHHV515-8L

فيديوهات أخرى
September 11, 2025

ملف الشركة

فيديوهات أخرى
September 13, 2024

XHGG501D تحديد خطأ الكابل

فيديوهات أخرى
November 05, 2024

XHCC-2/40

فيديوهات أخرى
September 17, 2025